The daily maintenance of Huaquan generator set is the key to ensuring their stable operation and extending their service life. Here is a detailed set of daily maintenance recommendations. I hope the following introduction can provide users with reference
1、 Replacement and Inspection of Filter for Huaquan Generator Set
Diesel filter: It is recommended to replace the filter every 500 hours for commonly used units and every two years for backup units to prevent oil blockage.
Oil filter: Regularly check the condition of the oil filter, and replace it promptly if it is damaged or clogged.
Air filter: Replace the filter element of the air filter in a timely manner to avoid the problem of decreased boost pressure caused by high intake resistance in the unit, as well as to prevent oil leakage from the turbocharger.
2、 Maintenance of Huaquan Generator Battery
Electrolyte level check: Regularly check the electrolyte level of the battery to ensure it is within the normal range, and replenish distilled water to maintain an appropriate electrolyte concentration.
Charging operation: Configure a high-quality charger and regularly perform equalization and float charging operations to maintain sufficient battery power.
3、 Maintenance of Huaquan generator set
Diesel moisture content inspection: Regularly check the moisture content of diesel to prevent corrosion and damage caused by condensed water entering the fuel tank.
Oil condition check: Pay attention to the condition of the engine oil and replace it regularly to maintain lubrication. At the same time, check the condition of components such as the oil filter, and replace them if they are damaged.
4、 Maintenance of cooling system for Huaquan generator set
Inspection of water pumps, water tanks, and water pipelines: Regularly inspect water pumps, water tanks, and water pipelines, clean scale and impurities, and ensure cooling effectiveness.
Leakage inspection: Check whether the water pipe joints, water tanks, and waterways are leaking, and repair them in a timely manner to avoid cooling system failure.
5、 Maintenance of Fuel and Gas Distribution System for Huaquan Generator Set
Fuel system cleaning: Regularly clean the fuel system, replace filter components, and ensure smooth fuel supply.
Valve system adjustment: Adjust the valve system to ensure even ignition and improve combustion efficiency.
6、 Inspection of Control System for Huaquan Generator Set
Line connector inspection: Check the control part of the generator set, including whether the line connectors are loose.
AVR module inspection: Ensure that the AVR module (automatic voltage regulator) is working properly to maintain a stable output voltage.
7、 Precautions for long-term shutdown of Huaquan generator set
Regular trial operation: If the emergency generator set is not in use for a long time, regular trial operation should be carried out to carefully check whether the oil level and coolant level are within a reasonable range, record the relevant parameters of equipment operation, and ensure the normal operation of the equipment.
Battery maintenance: During storage, the battery may discharge naturally, so it is necessary to check the battery's charge status and clean the battery terminals before restarting to ensure that the battery wires are firmly connected
In summary, the daily maintenance of Huaquan generator sets involves multiple aspects, including filter replacement and inspection, battery maintenance, engine maintenance, cooling system maintenance, fuel and valve system maintenance, control system inspection, long-term shutdown precautions, and other maintenance matters. By following these maintenance guidelines, it is possible to ensure reliable operation of the Huaquan generator set at critical moments and extend its service life.